Quick answer
The street was dark for three hours. The house with the backup gateway kept the fridge, the router and one lighting circuit. It did not keep the oven, the shower or the charger. That was the list they had paid for, and it worked.
The cut
The outage was a winter evening in Cardiff, after a fault on the local network rather than a planned job. It started just after 18:00 and the lights on the rest of the street came back a little after 21:00. The house in this note had finished its battery install six weeks earlier.
The pack is about 10 kWh on the badge, with a reserve of 30 percent held for backup. That reserve is the only energy the gateway (the box that disconnects from the street and keeps selected circuits alive) was allowed to spend once the grid disappeared. Three kilowatt-hours, not ten, was the budget for the evening.
The neighbours without a gateway had an ordinary blackout. Their solar inverters shut down as well. A grid-tied array does not power a house just because panels are on the roof.
The circuits that stayed
The essential board (the small second fuse board for backup circuits) has the fridge and freezer on one way, the router and the broadband box on another, the gas boiler controls on a third, and a single lighting circuit for the hall and the kitchen. The boiler itself is gas. It needed the controls and the pump, which are a small electrical load, and it kept the heating on.
Measured at the time, that set drew roughly 350 to 500 W once the fridge compressor cycled. At half a kilowatt, a 3 kWh reserve is several hours. The cut fitted inside the reserve with charge left over. Nobody boiled a kettle on that board, because the kettle circuit was not on it.
The owner had wanted the oven added during the sale. The installer had refused unless they accepted a much larger reserve and a shorter promise. A 3 kW oven would have eaten the reserve in about an hour, less if other things were on. Leaving the oven off the list is why the fridge was still cold at 21:00.
What did not happen
The solar did not recharge the pack during the cut. The gateway on this job was not set to allow the array to run while islanded (off-grid). That is an extra design, with earthing sorted out, not a default. For a three-hour winter evening it did not matter. For a daytime cut in June it would have been a missed chance.
The car charger stayed dead. So did the shower and the hob. The house was habitable. It was not a hotel. Anyone who expects a whole terrace to run as normal from a 10 kWh pack has not multiplied watts by hours.
Mobile signal was poor and the router's survival mattered more than the lighting. The owner worked from the kitchen table. That is a fair use of a small essential board. It is also a reason to put the router on the list on purpose, not hope it shares a socket with a lamp.
The label on the board
The next morning the installer, who had been told by text that the cut had happened, asked only whether the list matched what they had commissioned. It did. The owner wrote the circuits on a piece of tape inside the cupboard door so a guest would not plug a heater into the one socket that was live.
That tape is part of the system. Backup that depends on everyone remembering a conversation will be defeated by a fan heater. The socket on the essential circuit is either a known, labelled outlet or it should not exist.
If you are paying for a gateway, pay for the list in writing and for a test on the day. Throw the main switch, with the installer there, and see which rooms die. The Cardiff cut was the real test. The kitchen drill, done on commissioning day, is the one you are entitled to before you pay the final invoice.
Frequently asked questions
Why hold back 30 percent if the pack is 10 kWh?
So there is something left when the grid fails. The other 70 percent is for ordinary evenings. If you spend the whole pack before the cut, the gateway has nothing to give you. The reserve is the backup budget.
Could the solar have kept the house going all day?
Only with a gateway and an earthing design that allows the array to run off-grid, and only while the sun matches the load. This install did not include that. Winter evening solar would not have carried the house anyway.
Does a battery without a gateway do any of this?
No. A normal home battery disconnects when the grid does, so it does not energise a dead street cable. If the quote does not name a gateway or an essential board, assume the house goes dark with everyone else.
Get battery quotes in Cardiff
Figures here are a guide. An installer still needs to see your fuse board, where the battery will go and whether you want backup. Tell us your postcode and local installers will quote.