Quick answer

North-facing solar panels work in the UK, but how well depends almost entirely on the roof pitch. In our PVGIS 5.3 runs a 4 kWp north array at 15 degrees made 68% to 72% of what the same panels make facing south at 35 degrees, while at 35 degrees it fell to 50% to 56% and at 45 degrees to 41% to 48%. On a shallow north roof, payback in our model is about 14 to 18 years at today's price cap, against 10 to 13 years facing south, so it can be worth doing; on a steep one it is usually 18 to 25 years and rarely worth it on its own.

  • Pitch matters more than anything else: each extra 10 degrees of slope on a north roof costs about 8 percentage points of south output.
  • In June a north panel at 15 degrees makes 97% of a south panel in Birmingham; in December it makes 23%.
  • Payback for 4 kWp in our model: about 14 to 18 years at 15 degrees and 18 to 22 years at 35 degrees, panels only, at 26.32p.
  • Neither MCS nor the English planning rules treat north arrays differently: direction only changes the generation estimate.
  • North panels make most sense on a low pitch, as the second slope of a two-sided job, or where a battery or EV can use long summer days.
  • These are modelled figures for an unshaded roof. We have not tested any north-facing system.

How we ran the numbers

On 29 November 2026 we ran the European Commission's PVGIS 5.3 calculator through its PVcalc API for 84 cases: six cities (Brighton, Plymouth, London, Birmingham, Manchester and Glasgow), north at pitches of 10, 15, 25, 35 and 45 degrees, south at the same five pitches, and east and west at 15 and 35 degrees. Every run used 4 kWp of crystalline silicon panels, the PVGIS default of 14% system losses and no shading beyond the terrain horizon PVGIS adds itself.

Each call took the form PVcalc?lat=52.4862&lon=-1.8904&peakpower=4&loss=14&angle=15&aspect=180&outputformat=json, with the latitude, longitude, angle and aspect changed for each case. In the PVGIS API, aspect is the direction the panel faces: 0 for south, 90 for west and -90 for east, so we used 180 for north. PVGIS logs 180 as -179 degrees; a test at 179 for London gave 2,160 kWh against 2,162 kWh, so the one degree makes no practical difference. The coordinates are the city centre points we use across the site. Weather data is the PVGIS-SARAH3 satellite record for 2005 to 2023.

North output as a share of south, by pitch

The table shows the Birmingham result in kWh a year and the range across all six cities. The last column compares each north pitch with the best common south roof, 35 degrees, which is the comparison most homeowners care about.

The pattern is the same in every city. A panel that lies almost flat sees mostly the sky overhead, and the direction it leans hardly matters. Tip it towards north and it turns its face away from the low sun for most of the year. By 45 degrees a north array in Birmingham makes 1,792 kWh, less than half of a south one.

4 kWp facing north, PVGIS 5.3, 14% losses, run 29 November 2026
North pitchBirmingham, kWh a yearShare of south at same pitchShare of south at 35 degrees
10 degrees2,88281% to 83%73% to 76%
15 degrees2,72073% to 76%68% to 72%
25 degrees2,40861% to 65%59% to 64%
35 degrees2,09650% to 56%50% to 56%
45 degrees1,79241% to 48%41% to 48%
  • South at 35 degrees, for comparison: 4,624 kWh in Brighton, 4,488 in Plymouth, 4,075 in London, 3,872 in Birmingham, 3,544 in Manchester and 3,410 in Glasgow.
  • East or west at 35 degrees in Birmingham: 3,102 and 3,026 kWh. A north roof at 15 degrees (2,720 kWh) is closer to an east roof than most people assume.
  • The north share is a little higher in Manchester and Glasgow (55% to 56% at 35 degrees) than on the south coast (50% to 52%), likely because cloudier skies give more diffuse light, which arrives from the whole sky rather than from the south.

Summer against winter

A north roof is a summer roof. Around midsummer the sun rises in the north east, sets in the north west and stands high at noon, so a shallow north panel catches nearly as much as a south one. In winter the sun stays low in the southern sky and a north panel sees almost none of it directly.

Across November to February, a north array at 15 degrees makes 27% to 30% of a south array at 35 degrees in our six cities; across May to August it makes 89% to 92%. In Glasgow that north array makes about 128 kWh over the four winter months, roughly a kilowatt hour a day from 4 kWp. Our guide on how much electricity a solar panel produces gives south figures per panel for more cities.

4 kWp in Birmingham by month, kWh (PVGIS 5.3)
MonthSouth, 35 degreesNorth, 15 degreesNorth, 35 degrees
January1493734
March336190118
May469425343
June468453383
July472445369
September361231143
November1694441
December1333127

What it means for payback

We used the same method as our solar panel payback guide, so the south figures here match it: a home using 2,500 kWh a year (Ofgem's medium typical value) that is in half the day, with the share of solar used in the house read from MCS MGD 003 table 7-12 at each array's yearly output. Electricity used is valued at the Ofgem cap of 26.32p per kWh (32.69p from 1 January 2027) and the rest is exported at 12p, the Outgoing Octopus rate. Install cost is the site's planning figure of £6,750 for 4 kWp, or £9,250 with a 5 kWh battery; see what solar panels cost for how that range was built. We assumed a north system costs the same as a south one.

A smaller output lifts the share MGD 003 says you use yourself, from 19% for a south array in Birmingham to 23% at 15 degrees north and 29% at 35 degrees. That softens the loss a little but does not close it.

Simple payback in years, 4 kWp panels only, at 26.32p / 32.69p
CitySouth, 35 degreesNorth, 15 degreesNorth, 35 degrees
Brighton10.2 / 9.514.2 / 13.118.3 / 16.5
Plymouth10.4 / 9.714.3 / 13.118.2 / 16.4
London11.4 / 10.515.6 / 14.219.7 / 17.8
Birmingham11.8 / 10.916.2 / 14.819.9 / 17.9
Manchester12.8 / 11.817.0 / 15.521.1 / 19.0
Glasgow13.3 / 12.317.9 / 16.222.3 / 20.0
  • Worked example, Birmingham at 15 degrees north: 2,720 kWh x 23% = 626 kWh used, worth £164.76 at 26.32p; 2,094 kWh exported at 12p earns £251.28. Total £416.04 a year, so £6,750 pays back in 16.2 years.
  • At 45 degrees north, payback runs from 21.5 years in Plymouth to 25 years in Glasgow at today's cap.
  • With a 5 kWh battery, MGD 003 gives a north array at 35 degrees in Birmingham 82% self-use, and payback at 32.69p falls to about 15.2 years. MGD 003 does not know the array faces north, and a north array fills a battery on far fewer winter days, so treat that figure with care.

What MCS and the planning rules say

MCS does not treat north arrays as a special case. Under MIS 3002 issue 6.0 the installer looks up a kWh per kWp figure for the postcode zone from MCS tables that run in 5 degree steps of orientation and 1 degree steps of pitch, then multiplies it by system size and a shade factor. Direction changes that number and nothing else. MGD 003 then works out self-use from the yearly figure, and says that for now no adjustment can be made for different layouts other than through the generation figure.

Two MCS points do matter on a north roof. MIS 3002 lists a pitch under 30 degrees as an unusual roof structure, where a qualified structural engineer must be consulted, and the shallow roofs that suit north panels often fall in that group. MCS's own tables also differ from a raw PVGIS run like ours, so expect the installer's forecast to differ a little.

In England, the permitted development rules for solar on houses (GPDO Schedule 2, Part 14, Class A, as amended from 27 August 2026) limit how far panels stick out and how high they go, and exclude listed buildings, scheduled monuments and some walls in conservation areas. We found no condition about which way the panels face.

When north panels make sense

The north roof is rarely the first choice, but it can be a sensible second one. These are the cases where our numbers support it.

  • A low pitch, roughly 20 degrees or less, on a house with no better roof face. At 15 degrees you keep about 70% of south output.
  • As the second slope of a roof that already has panels on the south, east or west side. Scaffold and the survey are already being paid for, and each extra north kWp at 15 degrees in Birmingham adds about 680 kWh a year, worth about £82 if all exported at 12p or £179 if all used at 26.32p. Our east-west guide covers wiring two slopes to one inverter, which applies here too.
  • A home with a battery or an EV that soaks up long summer days. North output peaks from May to August, when a battery can hold the surplus for the evening.
  • A low-pitch extension or garage roof facing north. If the roof is flat rather than pitched, frames let you face the panels any way you like, so there is no reason to point them north; see solar panels on a flat roof.

When to leave a north roof bare

Before you decide, run your own roof in the solar panel calculator or in PVGIS, and ask any installer for the MCS estimate for the north slope on its own. For quotes, use our battery and solar quotes page.

  • Pitches of 35 degrees and steeper. Output drops to about half of south or less and payback in our model runs past 18 years.
  • Any real shade. A north roof starts with little winter light, and a chimney or tree can remove most of what is left.
  • If the aim is winter savings. From November to February a north array makes about a quarter of what a south one does, so a battery charged on a cheap overnight tariff does more for winter bills.
  • Where a garden, outbuilding or another roof faces south. A ground mount or a different roof will usually beat the north slope.

G98 and G99 paperwork

Not sure which form your system needs?

The free route finder works out whether your solar or battery is G98, or G99 SGI-1, SGI-2 or SGI-3, from the inverter sizes. The £19 pack then fills in the form data, the evidence checklist and the letters for your network operator.

Frequently asked questions

Are north-facing solar panels worth it in the UK?

On a shallow roof they can be. At 15 degrees our PVGIS runs give 68% to 72% of a south roof and payback of about 14 to 18 years at the current cap. At 35 degrees or steeper, output falls to about half of south and payback runs to 18 years or more, which rarely makes sense.

How much does a north-facing solar array produce?

A 4 kWp north array in Birmingham makes about 2,720 kWh a year at 15 degrees, 2,408 kWh at 25 degrees, 2,096 kWh at 35 degrees and 1,792 kWh at 45 degrees in PVGIS 5.3, against 3,872 kWh facing south at 35 degrees.

Do north-facing panels work in winter?

Barely. In December a 4 kWp north array at 15 degrees in Birmingham makes about 31 kWh in PVGIS, against 133 kWh facing south. In Glasgow the whole November to February total is about 128 kWh.

Do I need planning permission for panels on a north roof?

Not because of the direction. The English permitted development conditions for solar on houses cover projection, height, listed buildings, conservation areas and scheduled monuments, and say nothing about which way panels face.

Will an MCS installer fit panels on a north roof?

MCS rules do not forbid it. The installer must give you a generation estimate from the MCS tables for your pitch and orientation and a self-use estimate from MGD 003 before the contract is awarded, so you can see the expected output before you sign.

Want a real price for your home?

Figures here are a guide. An installer still needs to see your fuse board, where the battery will go and whether you want backup. Tell us your postcode and local installers will quote.

Get free quotes

Related guides

Sources