Quick answer

To generate as much electricity as you use in a year, most UK homes need 4 to 10 solar panels of 430 watts. A home on Ofgem's medium figure of 2,500 kWh needs about 6 panels in London or Birmingham and 7 in Manchester or Glasgow, going by our PVGIS 5.3 runs, while homes with an EV or heat pump on a two-rate meter (Ofgem's high multi-rate figure is 6,100 kWh) need 12 to 17. There is no planning limit on the number of panels on a house roof in England: the usable roof, the MCS 400 mm edge margin and the inverter size your network operator accepts set the real limit.

  • Ofgem medium use, 2,500 kWh: 5 panels in Brighton, 6 in Birmingham, 7 in Glasgow (430 W, south, 35 degrees)
  • Ofgem high single-rate use, 3,800 kWh: 8 to 10 panels
  • Each panel takes about 2 square metres of roof; leave 400 mm clear at every roof edge under MIS 3002
  • Permitted development in England sets no panel count for a house roof; the inverter rating decides G98 (3.68 kW per phase) or G99

How many panels by usage and city

The table takes Ofgem's typical domestic consumption values, the yearly usage figures it has used for price cap bills since 1 July 2026, and divides each one by what a single 430 watt panel produces in three cities. We ran the European Commission's PVGIS 5.3 calculator again on 28 November 2026 for 1 kWp facing south at 35 degrees, with 14% system losses and no shade, and scaled it to one panel: 497 kWh a year in Brighton, 438 kWh in London, 416 kWh in Birmingham, 381 kWh in Manchester and 367 kWh in Glasgow. Counts are rounded to the nearest whole panel.

Ofgem's single-rate figures are 1,600 kWh (low), 2,500 kWh (medium) and 3,800 kWh (high). Homes on a two-rate meter, which includes many with storage heaters, an EV or a heat pump, have their own figures of 1,900, 3,400 and 6,100 kWh. Ofgem does not publish these by number of bedrooms, so use the kWh on your own bill or supplier app if you have a year of it. For the two cities not in the table, a medium user needs about 6 panels in London and 7 in Manchester.

430 W panels needed to match yearly use (Ofgem 2026 TDCVs, PVGIS 5.3, south at 35 degrees)
Ofgem usage levelBrightonBirminghamGlasgow
Low, single rate: 1,600 kWh3 (1.3 kWp)4 (1.7 kWp)4 (1.7 kWp)
Medium, single rate: 2,500 kWh5 (2.2 kWp)6 (2.6 kWp)7 (3.0 kWp)
High, single rate: 3,800 kWh8 (3.4 kWp)9 (3.9 kWp)10 (4.3 kWp)
Medium, multi-rate: 3,400 kWh7 (3.0 kWp)8 (3.4 kWp)9 (3.9 kWp)
High, multi-rate: 6,100 kWh12 (5.2 kWp)15 (6.5 kWp)17 (7.3 kWp)

Matching your usage is the floor, not the target

A system that makes as much as you use over a year still leaves you buying power most evenings and most of the winter. Output is lopsided: in our PVGIS runs a 430 watt panel in Glasgow makes about 0.27 kWh a day in December against 1.58 kWh a day in June. So if the roof allows, it can make sense to fit more than the table's count and export the summer surplus under the Smart Export Guarantee.

Panel rating and system size are linked by simple arithmetic: kWp is the number of panels times the wattage, divided by 1,000. Ten 430 watt panels are 4.3 kWp, and 24 make the 10.32 kWp system in our 10 kW solar system guide.

How to work it out for your home

Find your annual electricity use in kWh on a bill or in your supplier's app. Divide it by the yearly output of one panel where you live: for a 430 watt panel facing south, our PVGIS 5.3 runs give about 438 kWh in London, 416 kWh in Birmingham and 367 kWh in Glasgow, and about 370 to 500 kWh across the UK. A home in Birmingham using 3,400 kWh would need about eight panels to generate as much as it uses over a year. Allow about 2 square metres of roof per panel.

That does not mean you will use it all. Solar arrives in the middle of the day and mostly in summer, so without a battery a typical home uses only part of it directly: the MCS self-consumption tables (MGD 003) give about 14% to 23% for a home using 2,500 kWh a year with a 4 kWp array, the top figure if someone is in during the day, more for bigger users. The rest is exported and earns a payment. Our solar panel calculator does this sum for your region, and our table of how much electricity one solar panel produces gives the per panel figure for ten cities.

Roof space, direction and shade

Most home panels on UK quotes measure about 1.73 to 1.80 metres by 1.12 to 1.13 metres, close to 2 square metres each, according to the makers' datasheets in our solar panel sizes guide. South-facing is best, but east and west roofs produce about a fifth less (19% to 23% in our PVGIS runs) and spread generation across the morning and evening. North-facing roofs are usually not worth using.

Shade from chimneys, dormers and trees matters. If part of the roof is shaded for some of the day, optimisers or microinverters stop one shaded panel dragging down the rest.

How many solar panels can I have?

There is no maximum number of panels in the planning rules for a house roof in England. Class A of Part 14 of the General Permitted Development Order, as amended by SI 2026/896 from 27 August 2026, limits how far panels stand off the roof (0.2 metres on a pitched roof, and no higher than the highest part of the roof) and how high they sit on a flat roof (0.6 metres), but it sets no count, no area and no kW figure for roof panels. It only covers microgeneration, which the Energy Act 2004 defines as up to 50 kW of electrical capacity, far above any house roof. Listed houses have been outside permitted development since 27 August 2026, and each stand-alone garden array is limited to 9 square metres of panel, about four panels (since 27 August 2026 the old one-array limit applies only to blocks of flats, not houses). Our planning permission guide has the full list, and Scotland, Wales and Northern Ireland have their own rules.

In practice three other things set the number. The first is roof area after the edge margin. MCS installers work to MIS 3002, and clause 5.9.7 of issue 6.0 says panels should not be mounted within 400 mm of any edge of a domestic roof unless extra measures are taken against wind uplift and other risks. On a plain roof face 8 metres wide and 5 metres up the slope, that leaves room for 12 standard panels, as the worked example in our sizes guide shows. Chimneys, vents and roof windows take more.

The network limit: G98, G99 and export limits

The second limit is the network, and it turns on the inverter rating, not the panel count. Under G98, a system of up to 16 A per phase, which is 3.68 kW on a normal single-phase supply, is fitted first and the network operator is told within 28 days. Anything larger falls under G99 and needs the operator's approval before installation, usually through a fast track route for home systems. Panels can add up to more than the inverter: our 10 kW solar system guide explains how the operator assesses the inverter, and G98 and G99 covers the SGI-1 to SGI-3 routes.

The third limit is export. Where the local network has little spare capacity, the operator can approve a larger system on condition that an export limitation scheme caps what the house sends out. SSEN's G98 page says such a scheme can be cheaper than network upgrades and quicker to connect, and that permitted generation for homes is typically 5 kW to 15 kW. An export limit does not stop you fitting more panels; it means surplus above the cap is used, stored or wasted rather than exported. Find your operator with the DNO lookup tool.

Adding a battery, an EV or a heat pump

Ofgem's high figure for a two-rate meter is 6,100 kWh a year, which on our table means 12 panels in Brighton and 17 in Glasgow just to match the year. If your bill shows more than that, the roof rather than the bill is likely to set the number. A battery does not change how many panels you need, but it changes how much of their output you use: for a 2,500 kWh home with 4 kWp, the MCS MGD 003 tables give about 14% to 23% without a battery and about 52% to 57% with a battery of about 5 to 6 kWh usable. A 4 kWp array pairs well with 5 to 10 kWh of storage, and at 9.1 to 10 kWh usable MGD 003 gives about 59% to 60%, so the larger size adds only a few points for this home. See the battery sizes UK homes use and solar panel cost.

Before you ask for quotes

Bring three numbers to the survey: your yearly kWh from a bill, the roof faces you would use, and whether you plan an EV, a heat pump or a battery in the next few years. An installer can then size the array to the roof and the inverter to the network route, rather than the other way round. Our solar panel calculator gives a first estimate for your region, and you can then get quotes from local installers.

G98 and G99 paperwork

Not sure which form your system needs?

The free route finder works out whether your solar or battery is G98, or G99 SGI-1, SGI-2 or SGI-3, from the inverter sizes. The £19 pack then fills in the form data, the evidence checklist and the letters for your network operator.

Frequently asked questions

How many solar panels do I need to power a house?

To generate as much as an average home uses in a year, about 5 to 7 panels of 430 watts for Ofgem's medium figure of 2,500 kWh, depending on where you live. That will not power the house at night or cover most of the winter, which is why it can pay to fit more panels or add a battery.

How many solar panels do I need for a 3 bed house?

Ofgem does not publish usage by bedrooms, so start from your bill. At Ofgem's medium figure of 2,500 kWh, our PVGIS 5.3 runs give 5 panels in Brighton, 6 in Birmingham and 7 in Glasgow to match the year; at the high figure of 3,800 kWh, 8 to 10.

What is the maximum number of solar panels allowed in the UK?

In England there is no panel count in the permitted development rules for a house roof, only limits on how far panels stand off the roof. The real limits are roof area after the MCS 400 mm edge margin, and the inverter size your network operator accepts under G98 or G99.

How many solar panels can I have without DNO approval?

It depends on the inverter, not the panels. Up to 16 A per phase, about 3.68 kW on a single-phase supply, is G98 and only needs notifying within 28 days of commissioning. A larger inverter needs G99 approval before it is fitted.

How much roof space do I need for solar panels?

About 2 square metres per panel, plus a 400 mm margin at every roof edge under MIS 3002. Ten panels cover roughly 20 square metres of usable roof.

How much electricity does one solar panel produce?

A 430 watt panel facing south produces about 370 to 500 kWh a year in the UK, depending on location: about 438 kWh in London, 416 kWh in Birmingham and 367 kWh in Glasgow in our PVGIS runs. Direction and shade lower it.

Want a real price for your home?

Figures here are a guide. An installer still needs to see your fuse board, where the battery will go and whether you want backup. Tell us your postcode and local installers will quote.

Get free quotes

Related guides

Sources