Quick answer

You do not need a battery with solar panels: a panels-only system works on its own, you use what you can as it is generated and the surplus is exported, which earns money under the Smart Export Guarantee if you have an MCS certificate and a smart meter recording exports. In our worked example for a 4 kWp south-facing roof in Birmingham, adding a battery with 5.1 to 6 kWh usable was worth roughly £190 to £210 more a year at the October to December 2026 price cap, so skipping storage makes sense if your budget is tight, your export rate is decent, you do not need backup, and you choose an inverter that lets you add a battery later.

  • A 4 kWp south roof at 35 degrees in Birmingham is modelled by PVGIS 5.3 at about 3,872 kWh a year.
  • For a home using Ofgem's 2026 medium figure of 2,500 kWh, MCS MGD 003 puts panels-only self-consumption at 14% to 23% of generation, depending on who is home in the day.
  • A battery with 5.1 to 6 kWh usable lifts that to 52% to 57%, worth about £190 to £210 a year extra at 26.32p import and 12p export in our model.
  • The battery's value is roughly the kWh it shifts multiplied by the gap between your import and export rates; a narrow gap favours panels only.
  • Panels-only grid-tied systems shut down in a power cut, and a battery only helps if it is designed and approved to run in island mode.
  • If a battery is likely within a few years, ask for a hybrid inverter or a layout that suits a later AC-coupled battery.

What happens to your solar power without a battery

Without storage, solar electricity goes first to whatever is running in the house. Anything left over flows out through your meter to the grid. Nothing is wasted, but an exported kWh earns the export rate, while a kWh you use saves the full import price.

To be paid for exports you need a Smart Export Guarantee (SEG) tariff. MCS says you need a smart meter that records exported electricity and that suppliers may ask for your MCS certificate as proof the system was fitted by a certified installer with certified products. Ofgem says a SEG tariff must always stay above zero, and your SEG supplier does not need to be the company that supplies your import.

Our separate guide on whether solar panels are worth it covers regional output, and our solar panel payback guide works out the years to pay back by city. This page is about one decision: whether to leave the battery out.

The worked example: what we modelled

We used real public inputs, not a sales estimate. Every figure below is modelled, not measured, and we have not tested any system.

MGD 003 states its tables are averages for homes with similar occupancy, use and generation, not a prediction for one property. They exclude diverters, electric heating, heat pumps and EV charging. We also treated every kWh not self-used as exported, which ignores battery charging losses, so the battery's figures are slightly flattering.

  • Generation: PVGIS 5.3, 4 kWp, Birmingham (52.48 N, 1.89 W), 35 degree pitch facing due south, default 14% system loss. Result: 3,872 kWh a year, with a year-to-year standard deviation of about 137 kWh.
  • Use: 2,500 kWh a year, Ofgem's medium typical domestic consumption value for single-rate electricity from 1 July 2026 (low 1,600, high 3,800).
  • Self-consumption: MCS MGD 003 issue 2.0 lookup tables for 2,500 to 2,999 kWh use and the 3,600 to 3,899 kWh generation row, for each of its three occupancy archetypes.
  • Import price: 26.32p per kWh, the Ofgem cap average for Direct Debit from 1 October to 31 December 2026. Ofgem has set 32.69p for 1 January to 31 March 2027.
  • Export price: 12p per kWh, the Outgoing Octopus variable rate on Octopus Energy's page when we checked on 26 November 2026. It requires an Octopus import supply and a smart meter, and the rate can change.

Panels only versus panels and battery: the numbers

MGD 003 defines the archetypes by weekday occupancy: home all day means someone is usually in from 9am to 5pm, in half the day means empty for a morning or an afternoon, and out all day means typically empty on weekdays. MCS says to use the half-day table if you are not sure.

Annual value here is the import you avoid plus SEG income. It is not a bill, because the standing charge is unchanged.

Modelled annual value, 4 kWp, 3,872 kWh, 26.32p import, 12p export
Who is homeSelf-used, panels onlySelf-used, 5.1 to 6 kWh batteryValue: panels / battery
Home all day23% (891 kWh)57% (2,207 kWh)£592 / £781
In half the day19% (736 kWh)55% (2,130 kWh)£570 / £770
Out all day14% (542 kWh)52% (2,013 kWh)£542 / £753

Reading the example

The battery column uses MGD 003's band for 5.1 to 6 kWh of usable capacity. On these inputs it adds about £189 a year for a home-all-day household, £200 for half-day and £211 for out-all-day. At the January 2027 cap rate of 32.69p the gap widens to roughly £272, £288 and £304, while panels-only value rises to £577 to £649.

The rule of thumb behind those numbers is simple. A battery is worth roughly the extra kWh it lets you self-use, multiplied by your import rate minus your export rate. Here it shifts about 1,300 to 1,500 kWh a year, and the gap is 14.32p per kWh. If your export rate rises or your import rate falls, the battery earns less; the reverse makes it earn more. Our guide to exporting or storing solar runs the same comparison across export tariffs.

A bigger battery barely helps this household. Moving to the 9.1 to 10 kWh usable band raises self-consumption by only 3 to 6 points, because a home using 2,500 kWh a year has little evening demand left to cover. MGD 003 also caps the share of a home's use met by solar and storage at 90%.

For scale, our own planning range for a 5 kWh battery fitted on its own is £3,000 to £4,500, and £4,500 to £7,000 for 8 to 10 kWh, both at 0% VAT. These are our ranges, not quotes, and a battery added in the same job as panels may be priced differently. See our home battery cost guide for what changes them. Set against £189 to £211 a year, the battery in this example takes about 14 to 24 years to pay back at the October to December 2026 cap, or about 10 to 17 years at the January 2027 rate, before any time-of-use tariff income.

When to skip the battery: a decision checklist

Leaving storage out is reasonable if most of these apply to you. If two or more are false, get a quote both ways and ask for the MGD 003 figures with and without a battery; MGD 003 says both must be given to you.

  • Your export rate is close to your import rate, so the gap a battery earns is small.
  • You are home in the day, or can run the washing machine, dishwasher and EV charging while the sun is out.
  • Your annual use is modest, so evening demand is small.
  • You do not need power during a grid cut.
  • You would rather spend the budget on more panels now and add storage when you know your real usage.
  • You are not planning a time-of-use tariff where a battery charges cheaply overnight, which this example does not model.

Solar diverters: check what your hot water costs first

A solar diverter sends surplus solar to an immersion heater instead of exporting it. Myenergi says its eddi reacts in under a second and can heat water from less than 1 kW of surplus. MGD 003 leaves diverters out of its figures, so any gain is on top of the table above.

Whether a diverter pays depends on what it replaces. The Ofgem cap gas unit rate for October to December 2026 is 7.97p per kWh, below the 12p export rate in our example. So in a gas-boiler home on that export tariff, diverting a kWh into the tank saves less than exporting it earns. A diverter makes more sense if your water is heated by an immersion on peak electricity, or your export rate is low. Our guide on a battery with a solar diverter and hot water covers running both.

Power cuts: panels alone switch off

A standard grid-tied solar system does not keep your lights on in a power cut. National Grid's G98 guidance says the system will shut down during a power outage, and grid interface protection must be fitted and functionally tested.

A battery does not fix this by default. The ENA connection guide says storage designed to run in island mode during an outage cannot use the G99 fast-track route and goes through the standard G99 process. See solar during a power cut for what backup takes.

Choose an inverter now that suits a battery later

If you skip storage today, the inverter is the choice to get right. A hybrid inverter has a battery connection built in, so a later battery can plug into the same unit. A standard string inverter can still take a battery later through a separate AC-coupled inverter, at the cost of a second box and some extra wiring.

Check the grid rules too. Under the ENA guide, G98 covers a combined registered capacity up to 16A per phase, which is 3.68 kW on a single-phase supply, across all generators at the property. Adding a battery later can push the total over that line, which may need a G99 application or an export limiting scheme compliant with EREC G100. Our guide to adding a battery later explains the sequencing, and G98 and G99 for home batteries covers the paperwork.

G98 and G99 paperwork

Not sure which form your system needs?

The free route finder works out whether your solar or battery is G98, or G99 SGI-1, SGI-2 or SGI-3, from the inverter sizes. The £19 pack then fills in the form data, the evidence checklist and the letters for your network operator.

Frequently asked questions

Can solar panels work without a battery?

Yes. A grid-tied system powers the house while it generates and exports any surplus. You keep using grid electricity at night and on dull days. It stops during a power cut.

How much solar do you use without a battery?

It depends on your use, your system and when you are home. For a 4 kWp system making about 3,872 kWh a year in a home using 2,500 kWh, MCS MGD 003 tables give 14% to 23% of generation used in the home. Bigger users and people at home in the day use more.

Do I get paid for exported solar without a battery?

Yes, under the Smart Export Guarantee. You need an MCS certificate for the installation and a smart meter that records exports. Rates vary by supplier, must stay above zero, and you can choose an export supplier different from your import supplier, although some tariffs require you to buy from them too.

Is it cheaper to add a battery later?

Usually not: a later battery means a second visit, possibly a second inverter and new DNO paperwork for the combined capacity at the property. A hybrid inverter now keeps that extra cost down.

Should I get a diverter instead of a battery?

Only if the heat it makes is worth more than your export rate. With gas at the October to December 2026 cap rate of 7.97p and export at 12p, a gas-boiler home earns more by exporting. With an immersion on peak electricity or a low export rate, a diverter looks better.

Want a real price for your home?

Figures here are a guide. An installer still needs to see your fuse board, where the battery will go and whether you want backup. Tell us your postcode and local installers will quote.

Get free quotes

Related guides

Sources